21 resultados para clinical assessment tool

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis sets out to examine in detail the condition of systemic hypertension (high Blood Pressure) in relation to optometric practice in the United Kingdom. Systemic hypertension, which is asymptomatic in the early stages, is diagnosed from the Blood Pressure (BP) measurement recorded by a sphygmomanometer and/or from the complications that have developed in target organs. Optometric practice based surveys revealed that diagnosed systemic hypertension was the most prevalent cardiovascular medical condition (20.5%). Measurement of BP of patients in this sample revealed that if an optometrist included sphygmomanometry into the sight examination then at least one patient each day would be referred for suspect systemic hypertension. Optometric opinion felt that the measurement of BP in optometric practice would advance the profession, being appreciated by both patients and General Practitioners (GPs), but was felt to be an unnecessary routine procedure. The present sight examination for the systemic hypertensive is similar to that of the normotensive patient, but may involve an altered fundus examination and a visual field test. The GPs were in favour of optometric BP measurement and a future role in the share care management of the systemic hypertensive. The application of a new pictorial grading scale for the grading of vascular changes associated with pre-malignant systemic hypertension was found to be both accurate and reliable. Clinical trial of the grading scale in optometric practice found positive correlations between BP and increasing severity of the retinal vascular features. The subtle pre-malignant vascular changes require reliable accurate detection and analysis to assist in the management of the systemic hypertensive patient. Vessel width was shown to decrease with increasing age. Image analysis of the A/V ratio, arteriolar tortuosity and focal calibre changes revealed a positive correlation to the patient's BP (p<0.001). The retinal vasculature is relatively stable longitudinally with only minor changes in response to early disease states. Age and elevated BP increased a patient's risk of developing systemic medical conditions over a two-year period. The application of the pictorial grading scale to optometric practice and training the optometrist in the use of sphygmomanometry would improve the management of the systemic hypertensive patient in optometric practice. Future advances in image analysis hold substantial benefits for the detection and monitoring of subtle vascular changes associated with systemic hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recall of personal experiences relevant to a claim of food allergy or food intolerance is assessed by a psychologically validated tool for evidence that the suspected food could have caused the adverse symptom suffered. The tool looks at recall from memory of a particular episode or episodes when food was followed by symptoms resulting in self-diagnosis of food allergy or intolerance compared to merely theoretical knowledge that such symptoms could arise after eating the food. If there is detailed recall of events that point to the food as a potential cause of the symptom and the symptom is sufficiently serious, the tool user is recommended to seek testing at an allergy clinic or by the appropriate specialist for a non-allergic sensitivity. If what is recalled does not support the logical possibility of a causal connection between eating that food and occurrence of the symptom, then the user of the tool is pointed to other potential sources of the problem. The user is also recommended to investigate remedies other than avoidance of the food that had been blamed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the last decade we have seen an exponential growth of functional imaging studies investigating multiple aspects of language processing. These studies have sparked an interest in applying some of the paradigms to various clinically relevant questions, such as the identification of the cortical regions mediating language function in surgical candidates for refractory epilepsy. Here we present data from a group of adult control participants in order to investigate the potential of using frequency specific spectral power changes in MEG activation patterns to establish lateralisation of language function using expressive language tasks. In addition, we report on a paediatric patient whose language function was assessed before and after a left hemisphere amygdalo-hippocampectomy. Our verb generation task produced left hemisphere decreases in beta-band power accompanied by right hemisphere increases in low beta-band power in the majority of the control group, a previously unreported phenomenon. This pattern of spectral power was also found in the patient's post-surgery data, though not her pre-surgery data. Comparison of pre and post-operative results also provided some evidence of reorganisation in language related cortex both inter- and intra-hemispherically following surgery. The differences were not limited to changes in localisation of language specific cortex but also changes in the spectral and temporal profile of frontal brain regions during verb generation. While further investigation is required to establish concordance with invasive measures, our data suggest that the methods described may serve as a reliable lateralisation marker for clinical assessment. Furthermore, our findings highlight the potential utility of MEG for the investigation of cortical language functioning in both healthy development and pathology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To design and validate a vision-specific quality-of-life assessment tool to be used in a clinical setting to evaluate low-vision rehabilitation strategy and management. METHODS: Previous vision-related questionnaires were assessed by low-vision rehabilitation professionals and patients for relevance and coverage. The 74 items selected were pretested to ensure correct interpretation. One hundred and fifty patients with low vision completed the chosen questions on four occasions to allow the selection of the most appropriate items. The vision-specific quality of life of patients with low vision was compared with that of 70 age-matched and gender-matched patients with normal vision and before and after low-vision rehabilitation in 278 patients. RESULTS: Items that were unreliable, internally inconsistent, redundant, or not relevant were excluded, resulting in the 25-item Low Vision Quality-of-Life Questionnaire (LVQOL). Completion of the LVQOL results in a summed score between 0 (a low quality of life) and 125 (a high quality of life). The LVQOL has a high internal consistency (α = 0.88) and good reliability (0.72). The average LVQOL score for a population with low vision (60.9 ± 25.1) was significantly lower than the average score of those with normal vision (100.3 ± 20.8). Rehabilitation improved the LVQOL score of those with low vision by an average of 6.8 ± 15.6 (17%). CONCLUSIONS: The LVQOL was shown to be an internally consistent, reliable, and fast method for measuring the vision-specific quality of life of the visually impaired in a clinical setting. It is able to quantify the quality of life of those with low vision and is useful in determining the effects of low-vision rehabilitation. Copyright (C) 2000 Elsevier Science Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The combination of dimethyl dioctadecyl ammonium bromide (DDA) and the synthetic cord factor trehalose dibehenate (TDB) with Ag85B-ESAT-6 (H1 fusion protein) has been found to promote strong protective immune responses against Mycobacterium tuberculosis. The development of a vaccine formulation that is able to facilitate the requirements of sterility, stability and generation of a vaccine product with acceptable composition, shelf-life and safety profile may necessitate selected alterations in vaccine formulation. This study describes the implementation of a sterilisation protocol and the use of selected lyoprotective agents in order to fulfil these requirements. Concomitantly, close analysis of any alteration in physico-chemical characteristics and parameters of immunogenicity have been examined for this promising DDA liposome-based tuberculosis vaccine. The study addresses the extensive guidelines on parameters for non-clinical assessment, suitable for liposomal vaccines and other vaccine delivery systems issued by the World Health Organisation (WHO) and the European Medicines Agency (EMEA). Physical and chemical stability was observed following alteration in formulations to include novel cryoprotectants and radiation sterilisation. Immunogenicity was maintained following these alterations and even improved by modification with lysine as the cryoprotective agent for sterilised formulations. Taken together, these results outline the successful alteration to a liposomal vaccine, representing improved formulations by rational modification, whilst maintaining biological activity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

As a research group with no commercial interest in any macular pigment optical density (MPOD) measurement devices or nutritional supplements, we feel that we were well-placed to carry out an independent clinical assessment of the reliability of the MPS 9000 (Tinsley Precision Instruments, Redhill, Surrey, UK). Our study was prompted by the fact that we could not find any reported coefficient of repeatability value within the literature, and none was provided by the manufacturer.1 We had planned to use this instrument in our own research studies investigating the impact of nutritional supplementation on MPOD. For this purpose, we needed …

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In 2007 the UK Office of Government Commerce was mandated to carry out Procurement Capability Reviews (PCR) across the 16 top spending UK Government Departments. Since then, this programme has evolved into a self assessment based approach which is markedly different from the original approach. Will the move from a centre-led strategic review of procurement capability to a department-led model based on self assessment continue to strengthen and improve procurement capability across Central Civil Government? OGC is currently working with UK Government Departments to carry out their PCRs using a self-assessment tool which incorporates qualitative and quantitative measures. Results are generated based on a capability maturity model. The results are assured independently. OGC expectations are that tangible and measurable capability improvements will be realised when departments embed the self-assessment model and implement the findings as part of a continuous improvement regime. This paper is a case study, using some relevant literature to reflect on past and possible future development of the PCR self assessment scheme.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Gilles de la Tourette syndrome (GTS) is a chronic childhood-onset neuropsychiatric disorder with a significant impact on patients' health-related quality of life (HR-QOL). Cavanna et al. (Neurology 2008; 71: 1410-1416) developed and validated the first disease-specific HR-QOL assessment tool for adults with GTS (Gilles de la Tourette Syndrome-Quality of Life Scale, GTS-QOL). This paper presents the translation, adaptation and validation of the GTS-QOL for young Italian patients with GTS. METHODS: A three-stage process involving 75 patients with GTS recruited through three Departments of Child and Adolescent Neuropsychiatry in Italy led to the development of a 27-item instrument (Gilles de la Tourette Syndrome-Quality of Life Scale in children and adolescents, C&A-GTS-QOL) for the assessment of HR-QOL through a clinician-rated interview for 6-12 year-olds and a self-report questionnaire for 13-18 year-olds. RESULTS: The C&A-GTS-QOL demonstrated satisfactory scaling assumptions and acceptability. Internal consistency reliability was high (Cronbach's alpha > 0.7) and validity was supported by interscale correlations (range 0.4-0.7), principal-component factor analysis and correlations with other rating scales and clinical variables. CONCLUSIONS: The present version of the C&A-GTS-QOL is the first disease-specific HR-QOL tool for Italian young patients with GTS, satisfying criteria for acceptability, reliability and validity. © 2013 - IOS Press and the authors. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To investigate the use of MRIA for quantitative characterisation of subretinal fibrosis secondary to nAMD. Methods: MRIA images of the posterior pole were acquired over 4 months from 20 eyes including those with inactive subretinal fibrosis and those being treated with ranibizumab for nAMD. Changes in morphology of the macula affected by nAMD were modelled and reflectance spectra at the MRIA acquisition wavelengths (507, 525, 552, 585, 596, 611 and 650nm) were computed using Monte Carlo simulation. Quantitative indicators of fibrosis were derived by matching image spectra to the model spectra of known morphological properties. Results: The model spectra were comparable to the image spectra, both normal and pathological. The key morphological changes that the model associated with nAMD were gliosis of the IS-OS junction, decrease in retinal blood and decrease in RPE melanin. However, these changes were not specific to fibrosis and none of the quantitative indicators showed a unique association with the degree of fibrosis. Moderate correlations were found with the clinical assessment, but not with the treatment program. Conclusion: MRIA can distinguish subretinal fibrosis from healthy tissue. The methods used show high sensitivity but low specificity, being unable to distinguish scarring from other abnormalities like atrophy. Quantification of scarring was not achieved with the wavelengths used due to the complex structural changes to retinal tissues in the process of nAMD. Further studies, incorporating other wavelengths, will establish whether MRIA has a role in the assessment of subretinal fibrosis in the context of retinal and choroidal pathology

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neuropsychiatry services provide specialist input into the assessment and management of behavioral symptoms associated with a range of neurological conditions, including epilepsy. Despite the centrality of epilepsy to neuropsychiatry and the recent expansion of neuropsychiatry service provision, little is known about the clinical characteristics of patients with epilepsy who are routinely seen by a specialist neuropsychiatry service. This retrospective study filled this gap by retrospectively evaluating a naturalistic series of 60 consecutive patients with epilepsy referred to and assessed within a neuropsychiatry setting. Fifty-two patients (86.7%) had active epilepsy and were under the ongoing care of the referring neurologist for seizure management. The majority of patients (N = 42; 70.0%) had a diagnosis of localization-related epilepsy, with temporal lobe epilepsy as the most common epilepsy type (N = 37; 61.7%). Following clinical assessment, 39 patients (65.0%) fulfilled formal diagnostic criteria for at least one psychiatric disorder; nonepileptic attack disorder (N = 37; 61.7%), major depression (N = 23; 38.3%), and generalized anxiety disorder (N = 16; 26.7%) were the most commonly diagnosed comorbidities. The clinical characteristics of patients seen in specialist neuropsychiatry settings are in line with the results from previous studies in neurology clinics in terms of both epilepsy and psychiatric comorbidity. Our findings confirm the need for the development and implementation of structured care pathways for the neuropsychiatric aspects of epilepsy, with focus on comorbid nonepileptic attacks and affective and anxiety symptoms. This is of particular importance in consideration of the impact of behavioral symptoms on patients' health-related quality of life.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Distortion or deprivation of vision during an early `critical' period of visual development can result in permanent visual impairment which indicates the need to identify and treat visually at-risk individuals early. A significant difficulty in this respect is that conventional, subjective methods of visual acuity determination are ineffective before approximately three years of age. In laboratory studies, infant visual function has been quantified precisely, using objective methods based on visual evoked potentials (VEP), preferential looking (PL) and optokinetic nystagmus (OKN) but clinical assessment of infant vision has presented a particular difficulty. An initial aim of this study was to evaluate the relative clinical merits of the three techniques. Clinical derivatives were devised, the OKN method proved unsuitable but the PL and VEP methods were evaluated in a pilot study. Most infants participating in the study had known ocular and/or neurological abnormalities but a few normals were included for comparison. The study suggested that the PL method was more clinically appropriate for the objective assessment of infant acuity. A study of normal visual development from birth to one year was subsequently conducted. Observations included cycloplegic refraction, ophthalmoscopy and preferential looking visual acuity assessment using horizontally and vertically oriented square wave gratings. The aims of the work were to investigate the efficiency and sensitivity of the technique and to study possible correlates of visual development. The success rate of the PL method varied with age; 87% of newborns and 98% of infants attending follow-up successfully completed at least one acuity test. Below two months monocular acuities were difficult to secure; infants were most testable around six months. The results produced were similar to published data using the acuity card procedure and slightly lower than, but comparable with acuity data derived using extended PL methods. Acuity development was not impaired in infants found to have retinal haemorrhages as newborns. A significant relationship was found between newborn binocular acuity and anisometropia but not with other refractive findings. No strong or consistent correlations between grating acuity and refraction were found for three, six or twelve months olds. Improvements in acuity and decreases in levels of hyperopia over the first week of life were suggestive of recovery from minor birth trauma. The refractive data was analysed separately to investigate the natural history of refraction in normal infants. Most newborns (80%) were hyperopic, significant astigmatism was found in 86% and significant anisometropia in 22%. No significant alteration in spherical equivalent refraction was noted between birth and three months, a significant reduction in hyperopia was evident by six months and this trend continued until one year. Observations on the astigmatic component of the refractive error revealed a rather erratic series of changes which would be worthy of further investigation since a repeat refraction study suggested difficulties in obtaining stable measurements in newborns. Astigmatism tended to decrease between birth and three months, increased significantly from three to six months and decreased significantly from six to twelve months. A constant decrease in the degree of anisometropia was evident throughout the first year. These findings have implications for the correction of infantile refractive error.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Free Paper Sessions Design. Retrospective analysis. Purpose. To assess the prevalence of center-involving diabetic macular oedema (CIDMO) and risk factors. Methods. Retrospective review of patients who were screen positive for maculopathy (M1) during 2010 in East and North Birmingham. The CIDMO was diagnosed by qualitative identification of definite foveal oedema on optical coherence tomography (OCT). Results. Out of a total of 15,234 patients screened, 1194 (7.8%) were screen positive for M1 (64% bilateral). A total of 137 (11.5% of M1s) were diagnosed with macular oedema after clinical assessment. The OCT results were available for 123/137; 69 (56.1%) of these had CI-DMO (30 bilateral) which is 0.5% of total screens and 5.8% of those screen positive for M1. In those with CIDMO 60.9% were male and 63.8% Caucasian; 90% had type 2 diabetes and mean diabetes duration was 20 years (SD 9.7, range 2-48). Mean HbA1c was 8.34%±1.69, with 25% having an HbA1c =9%. Furthermore, 62% were on insulin, 67% were on antihypertensive therapy, and 64% were on a cholesterol-lowering drug. A total of 37.7% had an eGFR between 30% and 60% and 5.8% had eGFR <30. The only significant difference between the CIDMO and non-CIDMO group was mean age (67.83±12.26 vs 59.69±15.82; p=0.002). A total of 65.2% of those with CIDMO also had proliferative or preproliferative retinopathy in the worst eye and 68.1% had subsequently been treated with macular laser at the time of data review. Conclusions. The results show that the prevalence of CIDMO in our diabetic population was 0.5%. A significant proportion of macula oedema patients were found to have type 2 diabetes with long disease duration, suboptimal glycemic and hypertensive control, and low eGFR. The data support that medical and diabetic review of CIDMO patients is warranted particularly in the substantial number with poor glycemic control and if intravitreal therapies are indicated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background - The literature is not univocal about the effects of Peer Review (PR) within the context of constructivist learning. Due to the predominant focus on using PR as an assessment tool, rather than a constructivist learning activity, and because most studies implicitly assume that the benefits of PR are limited to the reviewee, little is known about the effects upon students who are required to review their peers. Much of the theoretical debate in the literature is focused on explaining how and why constructivist learning is beneficial. At the same time these discussions are marked by an underlying presupposition of a causal relationship between reviewing and deep learning. Objectives - The purpose of the study is to investigate whether the writing of PR feedback causes students to benefit in terms of: perceived utility about statistics, actual use of statistics, better understanding of statistical concepts and associated methods, changed attitudes towards market risks, and outcomes of decisions that were made. Methods - We conducted a randomized experiment, assigning students randomly to receive PR or non–PR treatments and used two cohorts with a different time span. The paper discusses the experimental design and all the software components that we used to support the learning process: Reproducible Computing technology which allows students to reproduce or re–use statistical results from peers, Collaborative PR, and an AI–enhanced Stock Market Engine. Results - The results establish that the writing of PR feedback messages causes students to experience benefits in terms of Behavior, Non–Rote Learning, and Attitudes, provided the sequence of PR activities are maintained for a period that is sufficiently long.